Data Sheet
Mark 3
Programmers and Timeswitches
3020P
4033
3060
A range of basic electro-mechanical time controls for
heating and domestic hot water systems, widely
favoured for their simplicity of operation. They have
been particularly popular for Local Authority
specification.
All models feature a 24-hour clock with colour coded
On and Off tappets, which are simply moved to the
desired time settings on the dial to provide up to 2 on
and 2 off periods per day.
The control module plugs in to a separate wallplate/
terminal block making installation and servicing as
simple as possible.
Factory Replacement Units
Plug-in modules are available for each model in the
Mark 3 range, including some units not in current
production. By removing the outer case and the two
screws holding the module to the wall mounting-plate,
the whole module assembly can be unplugged without
any disturbance to the electrical wiring, and the
replacement module simply plugged in.
Extremely easy to operate
Robust construction
Easy to install and wire
Replacement modules available
Proven reliability
Suited to all popular CH/HW systems
Low cost
Ordering
Type Reference
Features
Complete Time Controls
3020P
087N652600
24-hour Timeswitch. TIMED/OFF/ON (Constant). Water only/ Water &
Heating selection. Off and On override.
3060
087N652800
24-hour Programmer. Single rotary switch enables six most commonly
used CH and HW programmes to be easily selected.
4033
087N653000
24-hour Programmer. TIMED/OFF/ON (Constant) for heating and same
for domestic hot water. Off and On override.
Factory Replacement Units
3020P FRU
087N655700
Replacement Timeswitch Module
3060 FRU
087N659000
Replacement Programmer Module
4033 FRU
087N656000
Replacement Programmer Module
3022 FRU
087N655800
Replacement Optional Priority Timeswitch Module for Diverters
N.B. All units can be provided with Braille studding on request.
Data Sheet
Mark 3 Programmers and Timeswitches
Wiring Connections
1
2
3
4
5
6
7
E
N
L
3060 Programmer
&
3020P Timeswitch
N
HTG
HW
Mains Supply
1
2
3
4
5
6
7
E
N
L
4033 Programmer
HTG
HW
ON
OFF
ON
OFF
Mains Supply
Specification
These units should be installed in accordance with
I.E.E. Wiring Regulations by a competent electrician.
They should be wired through a Class A disconnect
such as a double-pole switched outlet or plug and
socket.
Generously sized terminals are clearly identified. All
units are supplied with full installation and operating
instructions.
Overall Dimensions
Width
102mm
Height
216mm
Depth
57mm
Voltage Rating
220/240 ac 50Hz
Max. Current Rating
3 amp. resistive
Max. Ambient Temp.
55°C
Danfoss Randall can accept no responsibility for possible errors in catalogues, brochures and other printed material, and reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
Danfoss Randall Ltd
Ampthill Road,
Bedford, MK42 9ER
Tel: 01234 364621 Fax: 01234 219705
Email: danfossrandall@danfoss.com
Website: www.danfoss-randall.co.uk
Part No. 040 Issue 2 03/00
Plik z chomika:
januszmaka
Inne pliki z tego folderu:
Installation Instructions.PDF
(384 KB)
Model 3020P.pdf
(126 KB)
Model 3060.pdf
(130 KB)
Model 4033.pdf
(133 KB)
Programmers & Timeswitches.PDF
(84 KB)
Inne foldery tego chomika:
CP715
FP715
GP Timeswitch
Replacement time controls
SET1E
Zgłoś jeśli
naruszono regulamin