1
HP Laserjet 5P, 5MP
HP Laserjet 6P, 6MP
Part Number: C3903A
Gram Load: 225 grams
Yield @ 5%: 4000 pgs
Pages/Min.: 6 ppm
Resolution: 600 dpi
Needle Nose Pliers
#1 Phillips Screwdriver
1/8” Flat Blade Screwdriver
Razor-type Cutter
Damp Cloth
Cotton Swabs
Anhydrous Isopropyl Alcohol
Vacuum or Compressed Air
SX Screws
5P Seal
5P Toner, 225 Grams
Conductive Grease
CORPORATE
LOS ANGELES
T
800 394.9900
818 316.0656
F
800 394.9910
818 313.9568
ATLANTA
T
877 676.4223
770 516.9488
F
877 337.7976
770 516.7794
Photo 1a
Step 1
Originally 5P cartridges are held together
with plastic clips, not screws. However, if
the cartridge has been remanufactured, it
may have up to seven screws (usually
Phillips head) on the outside that must
be removed. Some of these screws are
pointed out in photos #1a and #1b
(See Photo 1a and 1 b)
DALLAS
T
877 499.4989
972 840.4989
F
877 774.1750
972 840.1750
MIAMI
T
800 595.4297
305 594.3396
F
800 522.8640
305 594.3309
Photo 1b
NEW YORK
T
800 431.7884
631 345.0121
F
800 431.8812
631 345.0690
TORONTO
T
877 848.0818
905 712.9501
F
877 772.6773
905 712.9502
Photo 2
Step 2
Place the cartridge, top down, on the
work table with the drum up and the
drum gear to the right. With a small flat
blade screwdriver, release the first clip in
the square hole in the lower right corner
facing you.
(See Photo 2)
SYDNEY
T
02 9648.2630
F
02 9648.2635
Brand names and trademarks are the
properties of their respective holders
and are for descriptive use only.
Te chnical Resource Center:
Toll Free:
800 394.9900
Website:
www.futuregraphicsllc.com
857567406.133.png 857567406.144.png 857567406.155.png 857567406.166.png 857567406.001.png 857567406.012.png 857567406.023.png 857567406.033.png 857567406.044.png 857567406.055.png 857567406.065.png 857567406.076.png 857567406.087.png 857567406.093.png 857567406.094.png 857567406.095.png 857567406.096.png 857567406.097.png 857567406.098.png 857567406.099.png 857567406.100.png 857567406.101.png 857567406.102.png 857567406.103.png 857567406.104.png 857567406.105.png 857567406.106.png 857567406.107.png 857567406.108.png 857567406.109.png 857567406.110.png 857567406.111.png 857567406.112.png 857567406.113.png 857567406.114.png 857567406.115.png 857567406.116.png 857567406.117.png 857567406.118.png 857567406.119.png 857567406.120.png 857567406.121.png 857567406.122.png 857567406.123.png 857567406.124.png 857567406.125.png 857567406.126.png 857567406.127.png 857567406.128.png 857567406.129.png 857567406.130.png 857567406.131.png
 
2
VX Technical Instructions
Photo 3
Step 3
Next, lightly rotate the cartridge clock-
wise, with the drum gear closer to you,
and pry loose the clip below the metal
drum shaft.
(See Photo 3)
Photo 4
Step 4
Pry the two halves apart slightly. Now
rotate the cartridge counterclockwise
back to its original position and pry loose
the four clips facing you, starting with the
one on the drum gear end. Avoid break-
ing the plastic cartridge clips by using two
small flat blade screwdrivers.
(See Photo 4)
Photo 5
Step 5
Rotate the cartridge counterclockwise
again until the drum gear is away from you
and pry loose the clip below the other
drum axle. Pry the two halves apart slight-
ly on this end, but be careful-toner may
spill out!
(See Photo 5)
Photo 6a
Step 6
Pull the drum cover all the way back.
(See Photo 6a)
Then flip it down so it tucks in between the
toner hopper and stays out of the way.
(See Photo 6b)
Photo 6b
Need trust-worthy, detailed Technical
Instructions for another engine?
V isit: www.futuregraphicsllc.com
857567406.132.png 857567406.134.png 857567406.135.png 857567406.136.png 857567406.137.png 857567406.138.png 857567406.139.png 857567406.140.png 857567406.141.png 857567406.142.png 857567406.143.png 857567406.145.png 857567406.146.png 857567406.147.png 857567406.148.png 857567406.149.png 857567406.150.png 857567406.151.png 857567406.152.png 857567406.153.png 857567406.154.png 857567406.156.png 857567406.157.png 857567406.158.png 857567406.159.png 857567406.160.png 857567406.161.png 857567406.162.png 857567406.163.png 857567406.164.png 857567406.165.png
 
VX Technical Instructions
3
Photo 7
Step 7
Now, work your way around the cartridge,
carefully prying the two halves apart.
Separate the waste hopper from the toner
hopper. Toner will spill everywhere.
(See Photo 7)
Photo 8
Step 8
Remove the toner mixing drive gear and
PCR from the toner hopper and set them
aside. Dump the toner out and clean
thoroughly with a vacuum or com-
pressed air.
(See Photo 8)
Photo 9
Step 9
The cartridge must be sealed before
toner can be installed. Remove the fill
plug and clean the surface to be sealed
with cotton swabs and alcohol.
(See Photo 9)
Photo 10
Step 10
Remove the non-stick backing from the
adhesive seal and lay in place with the tail
away from the plug end.
(See Photo10)
Photo 11
Step 11
Fill with toner using a funnel cap bottle
and re-install the plug in the toner hop-
per.
(See Photo11)
Need help with a particular remanu-
facturing problem?
Call the Technical Resource Center from
8am - 5pm PST: 800 394.9900
857567406.167.png 857567406.168.png 857567406.169.png 857567406.170.png 857567406.171.png 857567406.172.png 857567406.173.png 857567406.174.png 857567406.175.png 857567406.002.png 857567406.003.png 857567406.004.png 857567406.005.png 857567406.006.png 857567406.007.png 857567406.008.png 857567406.009.png 857567406.010.png 857567406.011.png 857567406.013.png 857567406.014.png 857567406.015.png 857567406.016.png 857567406.017.png 857567406.018.png 857567406.019.png 857567406.020.png 857567406.021.png 857567406.022.png 857567406.024.png 857567406.025.png
 
4
VX Technical Instructions
Photo 12
Step 12
Re-install the toner mixer drive gear.
Clean the PCR with a damp cloth (or Nu-
Finish if preferred) and allow to dry. Clean
the PCR saddles with a cotton swab and
alcohol and re-install the PCR.
Set the
toner hopper aside until step 25.
(See Photo 12)
Photo 13
Step 13
Using your #1 Phillips screwdriver,
remove the two screws holding the wiper
blade to the waste hopper, then remove
the wiper blade.
(See Photo 13)
Photo 14
Step 14
Thread SX screw into the drum axle on
the gear end. Grip the screw head tightly
with needle nose pliers and pull it out
using a side-to-side motion.
(See Photo 14)
Photo 15
Step 15
Rotate the waste hopper end-for-end and
grasp the other drum axle at the notches
provided. Pull the axle straight out.
(See Photo 15)
Photo 16
Step 16
Remove the drum, wrap it in protective
cloth or paper, and set it aside until step
22.
(See Photo 16)
Need trust-worthy, detailed Technical
Instructions for another engine?
V isit: www.futuregraphicsllc.com
857567406.026.png 857567406.027.png 857567406.028.png 857567406.029.png 857567406.030.png 857567406.031.png 857567406.032.png 857567406.034.png 857567406.035.png 857567406.036.png 857567406.037.png 857567406.038.png 857567406.039.png 857567406.040.png 857567406.041.png 857567406.042.png 857567406.043.png 857567406.045.png 857567406.046.png 857567406.047.png 857567406.048.png 857567406.049.png 857567406.050.png 857567406.051.png 857567406.052.png 857567406.053.png 857567406.054.png 857567406.056.png 857567406.057.png
 
VX Technical Instructions
5
Photo 17
Step 17
Pry off the large white side plate. Lift off
the metal mag roller contact plate, clean
off the old conductive grease, and replace
with new conductive grease (or leave
dry).
(See Photo 17)
Photo 18a
Step 18
Pry the small white side plate off the
other end.
(See Photo 18a)
Push down and forward on the black mag
roller guide plate latch.
(See Photo 18b)
Push the mag roller forward and lift out.
Clean with isopropyl alcohol or commer-
cial mag roller cleaner. Clean the doctor
blade with isopropyl alcohol.
Photo 18b
Step 19
(Optional, but not recommended) If you
want to remove the doctor blade to clean
it, cut the foam seals and remove the
Phillips head screws. Lift the doctor blade
out, clean and re-install. Removing the
doctor blade for cleaning is not a good
enough reason to cut the seals. If it is nec-
essary to replace the doctor blade, how-
ever, then these seals must be cut.
(See Photo 19)
Photo 19
Photo 20
Step 20
Re-install the mag roller assembly gear
end first with the guide plate spring fac-
ing toward the slot. Snap it into position.
Then lay thermal roller down flat.
(See Photo 20)
Need help with a particular remanu-
facturing problem?
Call the Technical Resource Center from
8am - 5pm PST: 800 394.9900
857567406.058.png 857567406.059.png 857567406.060.png 857567406.061.png 857567406.062.png 857567406.063.png 857567406.064.png 857567406.066.png 857567406.067.png 857567406.068.png 857567406.069.png 857567406.070.png 857567406.071.png 857567406.072.png 857567406.073.png 857567406.074.png 857567406.075.png 857567406.077.png 857567406.078.png 857567406.079.png 857567406.080.png 857567406.081.png 857567406.082.png 857567406.083.png 857567406.084.png 857567406.085.png 857567406.086.png 857567406.088.png 857567406.089.png 857567406.090.png 857567406.091.png 857567406.092.png
 